IE5+ series

IE5 series of asynchronous motors
IE5+ series of asynchronous motors
This is a series of asynchronous motors with the highest efficiency ever reported.
We have developed a full technical documentation for production of asynchronous motors of IE5+ series including:
  1. a complete technical specification of the motor;
  2. a full specification of the stator winding and electromagnetic core of the motor;
  3. a complete design of the motor with all the components comprising STEP files for the components and for the motor assembly and accompanying drawings in a format preferred by the customer.

Presentation on the IE5+ series in English (click on the image to see the pdf file)

Presentation on the IE5+ series in Russian (click on the image to see the pdf file)

Our IE5+ motor designs provide:
  1. the highest efficiency reported for asynchronous motors;
  2. lowest operational costs for asynchronous motors on the market due to the highest efficiency and high power factor;
  3. comparable motor cost to the existing IE3 motors on the market (see Motor mass IE5+ vs IE3 below);
  4. full compliance with IEC 60034-40-1 2014.

Click on any of the sections below to expand its content.

Why IE5+?
  1. Our IE5+ motor designs have 20%-25% lower losses compared to IE4 as specified in IEC 60034-40-1 2014.
  2. Our IE5+ motor designs have high power factor.
  3. Our IE5+ motor designs share the same axis heights and the same output powers as in the existing series of asynchronous motors, namely IE1-IE4.
  4. Our IE5+ motor designs have the lowest operational costs for a series of asynchronous motors due to the highest efficiency ever reported and high power factor.
  5. The overall motor cost comprises the price of the motor and its operational costs. The overall motor cost of IE5+ motors made according to our designs would be the lowest compared to any existing series of asynchronous motors.
  6. There have been attempts to develop series of permanent magnet synchronous machines and BLDC permanent magnet motors with increased efficiency approaching the level of our IE5+ series. However permanent magnet machines have a higher price, which means that the price of IE5+ motors made according to our designs and, of course, the overall motor cost would remain unsurpassed.
  7. Our IE5+ motor designs comply with IEC standard on the starting torque. Therefore they do not require additional starting equipment and accompanying extra costs.
  8. Our IE5+ motor designs share a lot of parts with our IE3+ and IE4+ motor designs providing a reduction of manufacturing costs.

Efficiency of IE5+, IE4+ and IE3+ series

Motor mass IE5+ vs IE3

50Hz

Calculation of benefit of IE5+ vs IE3, 50Hz

Motor data for 3000 rpm, 2-pole, 50 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Efficiency at 100% load [%]Efficiency at 75% load [%]Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMotor mass [kg]
ADP56-S2-IE5560.09271171.472690.80.2263.940.3172.62.76.85
ADP56-L2-IE5560.12267471.472.570.10.770.3143.650.4282.622.497.32
ADP63-S2-IE5630.18270575.876.975.40.840.4074.190.6352.542.539.88
ADP63-L2-IE5630.25273178.78078.90.860.5354.520.8742.62.6310.6
ADP71-S2-IE5710.3728338282.179.90.860.7556.011.252.883.1314.4
ADP71-L2-IE5710.55284784.784.983.20.861.096.641.853.183.2716.4
ADP80-S2-IE5800.75289887.186.784.40.861.458.242.473.33.7223.3
ADP80-L2-IE5801.1289088.488.587.10.882.047.973.633.13.3625.5
ADP90-S2-IE5901.5290689.489.487.90.892.738.354.932.863.3633.5
ADP90-L2-IE5902.22915919189.80.893.918.727.212.763.4438.8
ADP100-S2-IE51003292791.691.690.40.95.258.19.792.063.1853.7
ADP112-S2-IE51124296493.59391.40.867.179.0112.91.63.8471
ADP132-S2-IE51325.529519392.791.20.899.558.4317.81.593.08100
ADP132-L2-IE51327.5295593.893.592.20.89138.4124.21.523.09114
ADP160-S2-IE516011296594.294930.918.88.3235.41.443.38159
ADP160-M2-IE516015296494.694.693.90.92258.248.31.463.27170
ADP160-L2-IE516018.5296494.99594.40.9230.68.0959.61.473.22183
ADP180-S2-IE518022296895.295.294.50.9136.78.6270.81.383.41230
ADP200-S2-IE520030296695.495.494.70.9249.38.2496.61.423.28310
ADP200-L2-IE520037296595.695.795.10.9260.68.251191.463.03322
ADP225-S2-IE522545296795.995.895.10.9273.47.961451.223.21420
ADP250-S2-IE525055297996.195.995.10.9290.28.561761.413.49548
ADP280-S2-IE528075298296.596.295.30.921219.312401.054.05797
ADP280-L2-IE528090298296.696.495.70.931459.152881.063.9822
ADP315-S2-IE5315110298296.896.6960.941019.243521.023.841041
ADP315-M2-IE5315132298196.996.896.30.941219.234231.073.781054
ADP315-L2-IE531516029819796.996.60.951469.185131.113.651093
ADP315-SL2-IE5315200298097.197.196.80.951818.796411.13.421149
ADP355-S2-IE5355250298697.497.396.90.952278.978000.883.561635
ADP355-M2-IE5355315298697.697.697.20.952858.9410070.913.481747
ADP355-L2-IE5355355298497.597.697.40.953208.5811360.913.251713
Line voltage 400 Y (from 0.09kW to 90kW), 400 Δ (from 110kW to 355kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP56-S2-IE5560.09271116824
ADP56-S2-IE5560.12267416319
ADP63-S2-IE5630.182705201232
ADP63-L2-IE5630.252731231336
ADP71-S2-IE5710.37283328735
ADP71-L2-IE5710.552847321041
ADP80-S2-IE5800.752898384179
ADP80-L2-IE5801.12890472169
ADP90-S2-IE5901.52906582481
ADP90-L2-IE5902.229157937116
ADP100-S2-IE5100329279413107
ADP112-S2-IE511242952132-4127
ADP132-S2-IE51325.52952140317457
ADP132-L2-IE51327.52955183331514
ADP160-S2-IE5160112966205431636
ADP160-M2-IE5160152964259682941
ADP160-L2-IE516018.529642937971090
ADP180-S2-IE518022296834311301474
ADP200-S2-IE520030296639813441742
ADP200-L2-IE520037296543616502086
ADP225-S2-IE522545296752220002523
ADP250-S2-IE525055297959324373030
ADP280-S2-IE528075298280031523951
ADP280-L2-IE528090298288435784463
ADP315-S2-IE53151102982106748285895
ADP315-M2-IE53151322981117755066683
ADP315-L2-IE53151602981129769938290
ADP315-SL2-IE53152002980149883089806
ADP355-S2-IE535525029862347985712204
ADP355-M2-IE5355315298633481242015768
ADP355-L2-IE5355355298436441474618390
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 1500 rpm, 4-pole, 50 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]*Efficiency at 100% load [%]*Efficiency at 75% load [%]*Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMotor mass [kg]
ADP56-S4-IE5560.0614107472.467.30.640.1823.960.4062.73.126.89
ADP56-L4-IE5560.09136374.975.773.40.740.2363.450.6312.132.317.29
ADP63-S4-IE5630.12137476.777.575.30.750.3023.410.8341.832.319.11
ADP63-L4-IE5630.18136378.480790.770.4313.51.261.892.0810.3
ADP71-S4-IE5710.25139881.582.4810.760.5864.061.711.952.2314.4
ADP71-L4-IE5710.37140684.885.4840.740.854.162.511.922.3117.9
ADP80-S4-IE5800.55144787.186.884.70.791.157.513.633.383.522.6
ADP80-L4-IE5800.75145288.488.286.30.81.547.684.933.653.8226.2
ADP90-S4-IE5901.1145189.689.688.30.812.187.77.243.123.3234.3
ADP90-L4-IE5901.5144990.190.489.50.832.897.469.882.963.1338.7
ADP100-S4-IE51002.2145091.391.891.30.844.136.9614.52.522.8154.3
ADP100-L4-IE51003145592.292.591.90.835.647.2819.72.553.0266.6
ADP112-S4-IE51124146792.993.192.40.877.137.92262.33.0476.9
ADP132-S4-IE51325.5147193.693.592.50.859.996.8335.71.622.76108
ADP132-L4-IE51327.514749493.992.90.8513.67.3848.61.692.98127
ADP160-S4-IE516011148294.594.493.60.8719.28.770.91.893.36185
ADP160-L4-IE516015148294.894.894.20.8825.98.9496.723.24207
ADP180-S4-IE518018.5148595.395.394.60.8931.68.341191.663.42255
ADP180-L4-IE518022148595.595.594.90.8937.38.341411.683.16270
ADP200-S4-IE520030148695.895.995.50.950.48.041931.473.09343
ADP225-S4-IE522537148996.296.295.70.961.88.562371.533.08437
ADP225-L4-IE522545148996.496.495.80.8975.48.272891.473.01477
ADP250-S4-IE525055148996.596.495.80.9190.38.613531.453.49640
ADP280-S4-IE528075148996.596.495.70.911238.14811.243.16848
ADP280-L4-IE528090148996.796.6960.921478.255771.33.15890
ADP315-S4-IE5315110148896.896.796.10.921037.447061.112.871186
ADP315-M4-IE5315132148896.996.896.20.921257.388471.122.831261
ADP315-L4-IE531516014899796.996.40.921497.8410261.232.911352
ADP315-SL4-IE5315200148897.19796.60.921887.5612831.22.781424
ADP355-S4-IE5355250148797.197.196.60.922357.1716051.132.61869
ADP355-M4-IE5355315148897.397.3970.922967.3620221.22.61981
ADP355-L4-IE5355355148897.497.497.20.923307.8322781.292.692026
Line voltage 400 Y (from 0.06kW to 90kW), 400 Δ (from 110kW to 355kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP56-S4-IE5560.06141012214
ADP56-L4-IE5560.09136314519
ADP63-S4-IE5630.12137416420
ADP63-L4-IE5630.18136315824
ADP71-S4-IE5710.251398181230
ADP71-L4-IE5710.371406231336
ADP80-S4-IE5800.55144727937
ADP80-L4-IE5800.751452341751
ADP90-S4-IE5901.11451454387
ADP90-L4-IE5901.514495277129
ADP100-S4-IE51002.214507183153
ADP100-L4-IE5100314559130121
ADP112-S4-IE51124146711562177
ADP132-S4-IE51325.51472145220366
ADP132-L4-IE51327.51474180118298
ADP160-S4-IE5160111482219142361
ADP160-L4-IE5160151482258178437
ADP180-S4-IE518018.51485318284602
ADP180-L4-IE5180221485338399738
ADP200-S4-IE5200301486417510926
ADP225-S4-IE52253714895106481158
ADP225-L4-IE52254514896068221428
ADP250-S4-IE525055148962427693393
ADP280-S4-IE528075148969434544148
ADP280-L4-IE528090148980041364936
ADP315-S4-IE5315110148892452696192
ADP315-M4-IE53151321488102360407063
ADP315-L4-IE53151601489118376318814
ADP315-SL4-IE531520014881301911410415
ADP355-S4-IE5355250148716381139313030
ADP355-M4-IE5355315148823681499317361
ADP355-L4-IE5355355148829281617819105
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 1000 rpm, 6-pole, 50 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]*Efficiency at 100% load [%]*Efficiency at 75% load [%]*Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMotor mass [kg]
ADP71-S6-IE5710.1891476.777.174.30.660.513.561.882.562.5113.3
ADP71-L6-IE5710.2592079.279.777.50.670.6763.762.62.532.5615.3
ADP80-S6-IE5800.3793181.982.781.20.720.9063.893.791.952.1720.9
ADP80-L6-IE5800.5594084.384.983.40.711.324.235.582.032.425.6
ADP90-S6-IE5900.7594786.286.985.90.731.724.337.571.872.1532.3
ADP90-L6-IE5901.194987.488.287.40.732.484.3411.11.782.1239.4
ADP100-S6-IE51001.59608989.488.50.733.354.5814.91.592.1253.1
ADP112-S6-IE51122.296789.889.988.70.784.56.8121.73.013.5164.3
ADP132-S6-IE5132397490.890.989.90.825.796.6129.42.093.0186.3
ADP132-L6-IE5132497491.591.690.70.837.646.5739.22.033.0299.3
ADP132-M6-IE51325.597892.492.591.50.8210.57.1653.72.313.34123
ADP160-S6-IE51607.598593.393.492.70.83146.972.71.732.8172
ADP160-L6-IE51601198693.893.8930.8120.86.251071.422.71199
ADP180-S6-IE51801598894.494.293.30.85277.741452.063.36265
ADP200-S6-IE520018.598994.994.994.30.88328.4317923.2331
ADP200-L6-IE5200229899595.194.50.8837.88.452132.113.03343
ADP225-S6-IE52253099095.695.795.20.89517.552891.562.89442
ADP250-S6-IE52503799295.795.995.50.962.47.743561.442.91577
ADP280-S6-IE52804599296.196.195.70.975.57.474331.272.89815
ADP280-L6-IE52805599296.296.395.90.991.77.385291.282.8859
ADP315-S6-IE53157599296.596.696.20.91247.137221.182.711100
ADP315-M6-IE53159099196.696.796.40.911486.88671.152.541139
ADP315-L6-IE531511099296.896.896.40.91826.8810591.142.61249
ADP315-SL6-IE531513299296.896.996.50.92186.7612711.132.521315
ADP355-S6-IE5355160993979796.60.921517.6615391.112.91778
ADP355-M6-IE535520099296.99796.70.921886.4419260.932.431813
ADP355-L6-IE535525099196.997.196.90.922356.2224080.922.311930
Line voltage 400 Y (from 0.18kW to 132kW), 400 Δ (from 160kW to 250kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP71-S6-IE5710.1891426834
ADP71-L6-IE5710.2592027430
ADP80-S6-IE5800.3793128635
ADP80-L6-IE5800.55940331245
ADP90-S6-IE5900.75946431962
ADP90-L6-IE5901.1949543184
ADP100-S6-IE51001.59606836105
ADP112-S6-IE51122.29678978167
ADP132-S6-IE51323974112168280
ADP132-L6-IE51324974132248380
ADP132-S6-IE51325.5978165324489
ADP160-S6-IE51607.5985211229440
ADP160-L6-IE516011986250323573
ADP180-S6-IE518015988306177483
ADP200-S6-IE520018.59893797831162
ADP200-L6-IE5200229893899451335
ADP225-S6-IE5225309905045301034
ADP250-S6-IE5250379925516181170
ADP280-S6-IE5280459926538471500
ADP280-L6-IE5280559927028521554
ADP315-S6-IE53157599288339284811
ADP315-M6-IE53159099189445165411
ADP315-L6-IE5315110992110857316839
ADP315-SL6-IE5315132992113271218252
ADP355-S6-IE5355160993131586139928
ADP355-M6-IE535520099213201114412464
ADP355-L6-IE535525099116981443016129
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 750 rpm, 8-pole, 50 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]*Efficiency at 100% load [%]*Efficiency at 75% load [%]*Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMotor mass [kg]
ADP80-L8-IE5800.2569578.378.275.20.610.7552.923.441.862.1420.3
ADP90-S8-IE5900.3771180.279.275.30.561.193.144.971.872.3225.6
ADP90-L8-IE5900.5571282.681.778.30.551.743.27.371.852.3230.9
ADP100-S8-IE51000.7572385.384.3810.542.363.749.91.822.5343.7
ADP100-L8-IE51001.172286.68683.20.563.33.6714.51.672.452.4
ADP112-S8-IE51121.570485.787.186.90.743.393.7920.41.571.8855.8
ADP132-S8-IE51322.272289.389.888.90.744.834.229.11.42.1493.3
ADP132-L8-IE5132372189.990.489.60.746.564.0839.71.322.05105
ADP160-S8-IE5160473491.291.690.80.758.484.8521.361.94154
ADP160-M8-IE51605.573491.391.991.40.7511.64.9171.61.381.93163
ADP160-L8-IE51607.57339292.692.20.7615.54.6697.71.31.82180
ADP180-S8-IE51801173792.893.192.40.7921.75.011431.382.26243
ADP200-S8-IE52001573793.393.793.30.8128.75.321941.342.08301
ADP225-S8-IE522518.573993.894.394.20.8334.35.312391.22.03376
ADP225-L8-IE5225227399494.594.40.8340.65.282841.22.02393
ADP250-S8-IE52503074394.995.194.70.8255.65.993861.212.41565
ADP280-S8-IE52803774495.595.5950.8268.26.494751.32.54809
ADP280-L8-IE52804574395.595.795.40.8481.15.855791.182.22856
ADP315-S8-IE5315557439696.195.70.8597.16.097071.22.271147
ADP315-M8-IE53157574396.396.395.80.841335.969641.142.241231
ADP315-L8-IE53159074396.296.496.10.851585.8711571.162.141296
ADP315-SL8-IE53151107419696.496.30.861935.1814171.051.841321
ADP355-S8-IE535513274396.396.596.40.881306.2116951.022.251710
ADP355-M8-IE535516074396.496.696.50.881576.1520551.022.191824
ADP355-L8-IE535520074496.596.796.60.881966.2725681.062.212003
Line voltage 400 Y (from 0.25kW to 110kW), 400 Δ (from 132kW to 200kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP80-L8-IE5800.25695391049
ADP90-S8-IE5900.3771140747
ADP90-L8-IE5900.5571248-939
ADP100-S8-IE51000.7572367-1156
ADP100-L8-IE51001.172280-1170
ADP112-S8-IE51121.57047361134
ADP132-S8-IE51322.272212446170
ADP132-L8-IE5132372114147187
ADP160-S8-IE51604734183101283
ADP160-M8-IE51605.573419883280
ADP160-L8-IE51607.5733242123364
ADP180-S8-IE518011737314159473
ADP200-S8-IE520015737363524887
ADP225-S8-IE522518.5739452156608
ADP225-L8-IE5225227394876691156
ADP250-S8-IE5250307436977704
ADP280-S8-IE52803774485611341990
ADP280-L8-IE52804574393215342466
ADP315-S8-IE531555743119718703067
ADP315-M8-IE53157574314628252287
ADP315-L8-IE531590743156811152683
ADP315-SL8-IE5315110741155014452995
ADP355-S8-IE5355132743186551607025
ADP355-M8-IE5355160743202825954623
ADP355-L8-IE5355200744232436245948
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

60Hz

Motor data for 3600 rpm, 2-pole, 60 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Efficiency at 100% load [%]Efficiency at 75% load [%]Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMass of active materials [kg]
ADP56-S2-IE5560.0933567472.868.30.80.1914.840.2563.23.46.85
ADP56-L2-IE5560.1233307574.470.60.770.2614.540.3443.23.17.32
ADP63-S2-IE5630.18334877.977.574.20.840.3455.040.51333.19.88
ADP63-L2-IE5630.25336980.780.677.90.850.4555.40.70933.210.6
ADP71-S2-IE5710.37345382.681.577.90.860.65671.023.33.714.4
ADP71-L2-IE5710.55346585.584.781.70.860.9367.781.523.63.816.4
ADP80-S2-IE5800.7535098785.682.20.861.269.422.043.64.323.3
ADP80-L2-IE5801.1350288.78885.50.881.779.1733.43.925.5
ADP90-S2-IE5901.5351689.688.886.40.882.379.54.073.13.933.5
ADP90-L2-IE5902.2352491.290.688.60.893.399.865.962.93.938.8
ADP100-S2-IE51003353591.891.189.10.94.559.118.12.23.653.7
ADP112-S2-IE51124356793.392.490.20.866.289.9610.71.64.371
ADP132-S2-IE51325.5355792.89289.80.98.299.414.81.63.5100
ADP132-L2-IE51327.5356093.792.9910.911.29.4120.11.63.5114
ADP160-S2-IE516011356994.293.6920.916.39.2729.41.53.8159
ADP160-M2-IE516015356894.894.493.20.9221.79.1540.11.53.7170
ADP160-L2-IE516018.5356895.194.893.80.9226.59.0349.51.53.6183
ADP180-S2-IE518022357195.394.993.80.9131.99.658.81.43.8230
ADP200-S2-IE520030357095.595.294.10.9242.79.1880.21.53.7310
ADP200-L2-IE520037356995.895.594.60.9252.39.22991.53.4322
ADP225-S2-IE522545357095.995.594.40.9263.78.851201.23.6420
ADP250-S2-IE525055358296.395.994.90.92789.551471.43.9548
ADP280-S2-IE528075358496.696.1950.9310510.3620014.5797
ADP280-L2-IE528090358496.896.495.40.9312510.22401.14.4822
ADP315-S2-IE5315110358496.996.695.70.9487.510.3429314.31041
ADP315-M2-IE531513235839796.896.10.9410510.343521.14.21054
ADP315-L2-IE5315160358397.29796.40.9512610.34261.14.11093
ADP315-SL2-IE5315200358297.397.296.70.951579.875331.13.81149
ADP355-S2-IE5355250358797.397.196.40.95197106650.941635
ADP355-M2-IE5355315358797.697.496.80.952469.988390.93.91747
ADP355-L2-IE5355355358697,697,597,10.952769.69450.93.61713
Line voltage 461 Y (from 0.09kW to 90kW), 461 Δ (from 110kW to 355kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [US$]Benefit react. IE3 [US$]Benefit total IE3 [US$]
ADP56-S2-IE5560.093356121021
ADP56-S2-IE5560.12333013215
ADP63-S2-IE5630.183348151226
ADP63-L2-IE5630.253369171027
ADP71-S2-IE5710.373453191432
ADP71-L2-IE5710.553465221739
ADP80-S2-IE5800.753509236588
ADP80-L2-IE5801.13502316192
ADP90-S2-IE5901.5351637341
ADP90-L2-IE5902.23524521264
ADP100-S2-IE510033535611374
ADP112-S2-IE51124356787-7611
ADP132-S2-IE51325.5355783-1073
ADP132-L2-IE51327.53560109-1495
ADP160-S2-IE5160113569131-6072
ADP160-M2-IE516015356817063234
ADP160-L2-IE516018.5356819778275
ADP180-S2-IE518022357122292314
ADP200-S2-IE52003035702580258
ADP200-L2-IE5200373569295153449
ADP225-S2-IE5225453570321186507
ADP250-S2-IE52505535824110411
ADP280-S2-IE52807535845259441469
ADP280-L2-IE5280903584592368960
ADP315-S2-IE5315110358471113772088
ADP315-M2-IE5315132358381210871898
ADP315-L2-IE5315160358393219952927
ADP315-SL2-IE53152003582110616402746
ADP355-S2-IE53552503587141110132425
ADP355-M2-IE53553153587206712773344
ADP355-L2-IE53553553586237429115284
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 1800 rpm, 4-pole, 60 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Efficiency at 100% load [%]Efficiency at 75% load [%]Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMass of active materials [kg]
ADP56-S4-IE5560.06172275,57367,10.60.1654.450.3333.13.86.89
ADP56-L4-IE5560.09168477,67773,30.70.2073.960.512.42.87.29
ADP63-S4-IE5630.12169379,178,474,90.720.2663.880.67722.89.11
ADP63-L4-IE5630.18168481,281,378,80.740.3734.041.022.12.510.3
ADP71-S4-IE5710.25171283,583,280,70.730.5144.61.392.12.614.4
ADP71-L4-IE5710.37171886,285,883,40.720.7464.642.062.12.717.9
ADP80-S4-IE5800.55175387,686,583,50.781.018.5233.74.122.6
ADP80-L4-IE5800.75175888,98885,30.781.368.74.0844.426.2
ADP90-S4-IE5901.1175690,289,687,50.81.918.75.983.43.834.3
ADP90-L4-IE5901.5175590,990,6890.822.528.468.163.23.638.7
ADP100-S4-IE51002.2175692,292,1910.833.597.86122.73.254.3
ADP100-L4-IE51003176092,992,791,60.824.98.1816.32.73.466.6
ADP112-S4-IE51124177193,493,191,90.866.228.8821.62.43.476.9
ADP132-S4-IE51325.5177593.893.391.80.858.637.6329.61.73.1108
ADP132-L4-IE51327.5177794.293.892.30.8511.78.2340.31.73.3127
ADP160-S4-IE516011178494.694.292.90.8716.79.7158.923.8185
ADP160-L4-IE51601517849594.793.60.8822.510.0180.32.13.6207
ADP180-S4-IE518018.5178795.595.1940.8927.49.2998.91.73.8255
ADP180-L4-IE518022178695.695.494.40.8932.39.31181.73.5270
ADP200-S4-IE520030178896.195.995.10.943.78.961601.53.5343
ADP225-S4-IE522537179096.39695.20.953.79.511971.63.5437
ADP225-L4-IE522545179096.596.295.30.8965.49.192401.53.4477
ADP250-S4-IE525055179096.496.195.10.9178.79.532931.53.9640
ADP280-S4-IE528075179096.796.495.50.911079.034001.23.5848
ADP280-L4-IE528090179096.896.695.80.921279.214801.33.5890
ADP315-S4-IE5315110179096.996.695.80.9289.18.345871.13.21186
ADP315-M4-IE531513217909796.795.90.921078.37041.13.21261
ADP315-L4-IE5315160179097.296.996.20.921298.88541.23.31352
ADP315-SL4-IE5315200179097.29796.40.921618.5210671.23.11424
ADP355-S4-IE5355250178997.196.996.20.922028.0813351.22.91869
ADP355-M4-IE5355315178997.397.296.60.922548.316811.22.91981
ADP355-L4-IE5355355178997.597.396.80.932848.8418941.332026
Line voltage 461 Y (from 0.06kW to 90kW), 461 Δ (from 110kW to 355kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [US$]Benefit react. IE3 [US$]Benefit total IE3 [US$]
ADP56-S4-IE5560.061722808
ADP56-L4-IE5560.09168410717
ADP63-S4-IE5630.12169312314
ADP63-L4-IE5630.181684121527
ADP71-S4-IE5710.25171214-410
ADP71-L4-IE5710.37171817219
ADP80-S4-IE5800.55175318220
ADP80-L4-IE5800.751758231235
ADP90-S4-IE5901.11756313868
ADP90-L4-IE5901.517553886124
ADP100-S4-IE51002.217565269121
ADP100-L4-IE51003176066-165
ADP112-S4-IE51124177180249329
ADP132-S4-IE51325.5177595179274
ADP132-L4-IE51327.51777117365482
ADP160-S4-IE5160111784143279422
ADP160-L4-IE5160151784174430604
ADP180-S4-IE518018.51787207569776
ADP180-L4-IE5180221786225718944
ADP200-S4-IE52003017882847481032
ADP225-S4-IE522537179033411051439
ADP225-L4-IE522545179038912741663
ADP250-S4-IE525055179038116952076
ADP280-S4-IE528075179047619492424
ADP280-L4-IE528090179055219222473
ADP315-S4-IE5315110179062928463475
ADP315-M4-IE5315132179069528073502
ADP315-L4-IE5315160179080433954199
ADP315-SL4-IE5315200179091233494261
ADP355-S4-IE53552501789104541865231
ADP355-M4-IE53553151789156739105477
ADP355-L4-IE53553551789194059447885
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 1200 rpm, 6-pole, 60 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Efficiency at 100% load [%]Efficiency at 75% load [%]Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMass of active materials [kg]
ADP71-S6-IE5710.18112679.478.574.70.630.4514.051.532.9313.3
ADP71-L6-IE5710.25113181.68177.80.640.64.242.112.8315.3
ADP80-S6-IE5800.37114184.183.881.20.70.7934.43.12.12.520.9
ADP80-L6-IE5800.55114886.185.883.40.691.164.744.572.22.825.6
ADP90-S6-IE5900.7511548887.986.10.711.54.866.2122.532.3
ADP90-L6-IE5901.1115689.189.187.60.722.164.869.091.92.439.4
ADP100-S6-IE51001.5116590.390.288.70.722.915.1312.31.72.453.1
ADP112-S6-IE51122.2117190.790.288.40.773.957.6617.93.3464.3
ADP132-S6-IE51323117791.591.189.30.815.17.3624.32.23.486.3
ADP132-M6-IE51324117792.191.890.20.816.717.332.52.13.499.3
ADP132-L6-IE51325.5118092.992.691.10.89.267.9444.52.43.8123
ADP160-S6-IE51607.5118793.893.592.30.8212.27.760.41.83.2172
ADP160-L6-IE516011118794.293.992.60.8118.16.9688.51.53.1199
ADP180-S6-IE518015119094.594.192.70.8423.68.611202.13.8265
ADP200-S6-IE520018.5119195.294.993.80.8727.99.411482.13.6331
ADP200-L6-IE520022119095.395.194.10.8832.99.461772.23.4343
ADP225-S6-IE522530119195.995.794.90.8944.38.412411.63.2442
ADP250-S6-IE52503711939695.995.20.8954.28.622961.53.3577
ADP280-S6-IE528045119396.496.295.50.8965.78.333601.33.2815
ADP280-L6-IE528055119396.596.495.80.979.78.244401.33.1859
ADP315-S6-IE531575119396.896.6960.91087.956001.231100
ADP315-M6-IE531590119296.896.896.30.911297.627211.22.81139
ADP315-L6-IE531511011939796.896.20.91587.698811.22.91249
ADP315-SL6-IE531513211939796.996.30.91897.5610571.12.81315
ADP355-S6-IE5355160119497.196.996.20.921308.5712801.13.31778
ADP355-M6-IE5355200119397.19796.50.921627.23160112.71813
ADP355-L6-IE5355250119297.297.196.70.92202720020.92.61930
Line voltage 461 Y (from 0.18kW to 132kW), 461 Δ (from 160kW to 250kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP71-S6-IE5710.18112619-415
ADP71-L6-IE5710.25113120020
ADP80-S6-IE5800.371141221537
ADP80-L6-IE5800.551148251642
ADP90-S6-IE5900.75115434-1321
ADP90-L6-IE5901.1115643043
ADP100-S6-IE51001.511655594149
ADP112-S6-IE51122.2117164167231
ADP132-S6-IE51323117778537615
ADP132-L6-IE51324117792714807
ADP132-S6-IE51325.51180115723838
ADP160-S6-IE51607.51187146216362
ADP160-L6-IE5160111187176320496
ADP180-S6-IE5180151190201495696
ADP200-S6-IE520018.51191254480734
ADP200-L6-IE52002211902687401009
ADP225-S6-IE522530119134512261571
ADP250-S6-IE525037119338615691955
ADP280-S6-IE528045119345812391697
ADP280-L6-IE528055119350213591861
ADP315-S6-IE531575119361719572574
ADP315-M6-IE531590119265623412997
ADP315-L6-IE5315110119377033714141
ADP315-SL6-IE5315132119380546655470
ADP355-S6-IE5355160119487356436516
ADP355-M6-IE5355200119395770397996
ADP355-L6-IE5355250119212661002111287
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load

Motor data for 900 rpm, 8-pole, 60 Hz
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Efficiency at 100% load [%]Efficiency at 75% load [%]Efficiency at 50% load [%]Power factor Cos φNominal current In [A]Start current Is/InNominal torque Tn [Nm]Start torque Tl/TnMax torque Tb/TnMass of active materials [kg]
ADP80-L8-IE5800.2585380.879.775.80.580.6723.242.822.520.3
ADP90-S8-IE5900.3786682.380.676.20.541.053.484.0822.725.6
ADP90-L8-IE5900.5586784.382.878.90.531.533.556.0622.730.9
ADP100-S8-IE51000.7587786.785.381.60.522.094.098.171.92.943.7
ADP100-L8-IE51001.18768886.983.80.542.924.02121.82.752.4
ADP112-S8-IE51121.58608888.587.50.732.944.2916.71.72.255.8
ADP132-S8-IE51322.287590.690.488.90.724.264.62241.52.493.3
ADP132-L8-IE5132387591.19189.60.725.764.532.81.42.3105
ADP160-S8-IE5160488692.292.190.80.747.375.3743.11.42.2154
ADP160-M8-IE51605.588692.592.591.50.74105.5259.31.42.2163
ADP160-L8-IE51607.58859393.192.30.7513.45.2380.91.42.1180
ADP180-S8-IE51801188993.593.492.20.7818.95.61181.42.6243
ADP200-S8-IE52001588994.194.193.30.8124.66.011611.42.4301
ADP225-S8-IE522518.589094.694.794.10.8329.65.961981.22.3376
ADP225-L8-IE52252289194.894.994.40.8335.15.922361.22.3393
ADP250-S8-IE52503089495.495.394.50.8248.46.653201.22.7565
ADP280-S8-IE52803789495.995.794.90.8159.77.213951.32.8809
ADP280-L8-IE5280458949695.995.30.8370.66.534811.22.5856
ADP315-S8-IE53155589496.396.295.60.8584.46.785881.22.51147
ADP315-M8-IE53157589496.596.495.70.841166.638011.22.51231
ADP315-L8-IE53159089496.696.5960.851376.559621.22.41296
ADP315-SL8-IE531511089296.596.696.30.861665.8211771.12.11321
ADP355-S8-IE535513289496.796.796.20.881126.97141012.51710
ADP355-M8-IE535516089496.896.896.40.881366.91170912.51824
ADP355-L8-IE535520089496.996.996.50.881697.0521351.12.52003
Line voltage 400 Y (from 0.18kW to 132kW), 400 Δ (from 160kW to 250kW)
*Efficiency is in accordance with IEC 60034-40-1 2014
Motor typeAxis height [mm]Output power [kW]Nominal speed [rpm]Benefit act. IE3 [EURO]Benefit react. IE3 [EURO]Benefit total IE3 [EURO]
ADP80-L8-IE5800.25853281139
ADP90-S8-IE5900.3786629736
ADP90-L8-IE5900.5586735-48-14
ADP100-S8-IE51000.7587747-80-34
ADP100-L8-IE51001.187657-95-38
ADP112-S8-IE51121.586062110171
ADP132-S8-IE51322.28758948136
ADP132-L8-IE5132387510320123
ADP160-S8-IE51604886131107238
ADP160-M8-IE51605.588615085235
ADP160-L8-IE51607.5885184153337
ADP180-S8-IE518011889227233460
ADP200-S8-IE520015889276299575
ADP225-S8-IE522518.5890338390729
ADP225-L8-IE522522891370476846
ADP250-S8-IE525030894490123613
ADP280-S8-IE5280378945896581247
ADP280-L8-IE52804589466312821944
ADP315-S8-IE53155589481919302750
ADP315-M8-IE53157589498812082195
ADP315-L8-IE531590894109622793375
ADP315-SL8-IE5315110892117621093285
ADP355-S8-IE5355132894133850756413
ADP355-M8-IE5355160894148447026185
ADP355-L8-IE5355200894170268578558
Benefit act. IE3 is benefit due to increased efficiency relative to a conventional average IE3 motor @ 100% load
Benefit react. IE3 is benefit due to due to increased power factor relative to a conventional average IE3 motor @ 100% load